Three-button colour-screen dive computer (wrist or console) with on-screen button labels, ZH-L16 ADT MB algorithm. Scuba (nitrox, optional multi-gas), Gauge and optional Apnea modes, MB levels, optional air integration, automatic altitude, rechargeable battery.
Buttons
| Button | Where | What it does |
|---|---|---|
| Left button | left of the three buttons; its current function is labelled on screen above it | Time of day: MENU (hold: O2 setting). In menus: ARROW or − . In a dive: BOOK (bookmark). |
| Middle button | middle of the three buttons; labelled on screen | Time of day: LOG (logbook). In menus: ARROW or + . In a dive: MORE (alternate information). |
| Right button | right of the three buttons; labelled on screen | Switches the G2 on. Time of day: LIGHT (hold: compass). In menus: ENTR / ARROW (next field) / SAVE; hold: back one level. |
Turn on / wake
Dive mode starts by itself at 0.8 m / 3 ft (p. 10).
Press the right button to switch the G2 on. It cannot be switched on while connected to USB.
PressRight button
Manual p. 11First start (or after a factory reset): follow the setup screens for language, units and time zone. Use left/middle to choose and right to confirm.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 11Each button's job is printed on screen above it (for example MENU, LOG, LIGHT). Labels change with the mode.
Manual p. 12In menus: press ENTR to go in, hold ENTR to go back a level.
PressRight buttonHoldRight button
Manual p. 18Hold the left and right buttons together to return to the time-of-day screen.
Hold togetherLeft buttonHold togetherRight button
Manual p. 18From the time-of-day screen, hold left and right together to switch it off. It also switches off after 3 minutes without use.
Hold togetherLeft buttonHold togetherRight button
Manual p. 17
Date and time
On the time-of-day screen, press MENU (left button).
PressLeft button
Manual p. 18Press the ARROW buttons to reach 7 Clock settings, then press ENTR.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 19Scroll to 7.2 Time and press ENTR. Here you set the time, time format (24h or AM/PM) and date.
PressMiddle buttonPressRight button
Manual p. 38Change the value with − and +. Press the right ARROW to go to the next field.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 18Press SAVE to store. Hold left and right together to return to the time of day.
PressRight buttonHold togetherLeft buttonHold togetherRight button
Manual p. 18For travel, 7.3 Time zone shifts the shown time by −13 to +14 hours in 15-minute steps.
Manual p. 38
Units (m/ft, °C/°F)
Press MENU, scroll to 9 Personalization and press ENTR.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 43Scroll to 9.4 Units and press ENTR.
PressMiddle buttonPressRight button
Manual p. 44Choose the combination of depth, temperature and pressure units with − and +, then press SAVE.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 44The units apply to the dive screen, logbook, alarm and altitude settings.
Manual p. 44
Water type (salt/fresh)
This setting changes depth in Scuba, Gauge and Apnea modes (p. 24).
Press MENU, go to 2 Dive settings and press ENTR.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 19Scroll to 2.5 Water type and press ENTR.
PressMiddle buttonPressRight button
Manual p. 23Choose Salt or Fresh with − and +, then press SAVE.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 24A wrong setting only changes the shown depth by about 3%; the decompression calculation uses pressure.
Manual p. 31
Dive mode (Air / Nitrox / Gauge)
Changing mode early requires a desaturation reset with code 313; never do this on a computer that will be dived (p. 23, 26).
Press MENU, go to 2 Dive settings, then 2.2 Dive mode and press ENTR.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 23Choose Scuba, Gauge or Apnea with − and +, then press SAVE. Apnea appears only if enabled in 8.7 Feature upgrade.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 23If it shows EXIT instead of SAVE, the mode cannot be changed yet: after a Scuba dive you must wait until desaturation is finished.
Manual p. 23Gauge only shows depth, time and temperature. No decompression, and most warnings and alarms are off.
Manual p. 81After a Gauge or Apnea dive you cannot switch back to Scuba for 48 hours, and no-fly time is 48 hours.
Manual p. 82If a deco stop is missed for more than 3 minutes it goes into SOS: no decompression computer for 24 hours.
Manual p. 13
Nitrox O₂% and ppO₂ limit
The manual does not state the factory default for the nitrox reset time; check menu 2.6 so you know whether O2% will return to 21% by itself (p. 24).
On the time-of-day screen, hold the left button to open the O2 setting (or press MENU, then ENTR on 1 O2 setting).
HoldLeft button
Manual p. 12Set O2% to the analysed tank with − and + (21–100%). The MOD is shown.
PressLeft buttonPressMiddle button
Manual p. 20Press the right ARROW to move to ppO2max and set it with − and +. The factory setting is 1.40 bar.
PressRight buttonPressLeft buttonPressMiddle button
Manual p. 18Press SAVE to store.
PressRight button
Manual p. 18To go back to air automatically: 2 Dive settings » 2.6 Nitrox reset time, 1–48 hours or 'no reset'.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 24T1 is the gas you start every dive with. For a normal one-tank dive, set only T1.
Manual p. 20
Conservatism / personal setting
Press MENU, go to 2 Dive settings, then 2.1 MB level and press ENTR.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 22Choose the level with − and +, then press SAVE.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 18Level 0 is the least conservative and level 9 the most conservative. Higher means more safety margin.
Manual p. 22If you skip a required MB level stop, the G2 lowers the active MB level by itself.
Manual p. 379.5 Workload (heart rate or breathing) can also make the decompression calculation more conservative when you work hard.
Manual p. 45
Altitude
Not available on this computer
Altitude is handled automatically: the G2 checks air pressure every 60 seconds and shows the altitude class and prohibited altitudes with a mountain symbol. Menu 5 Altimeter only shows/adjusts the elevation reading and does not change the altitude class (p. 34, 55).
Audible alarms (depth / time)
In Gauge mode most warnings and alarms are off; max depth and max dive time still work (p. 81).
Press MENU, go to 6 Warning settings and press ENTR.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 346.1 Maximum depth: set 5–100 m / 20–330 ft in 1 m / 5 ft steps.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 34For each warning choose OFF, visual, audible or BOTH. BOTH gives sound and screen message.
PressLeft buttonPressMiddle button
Manual p. 346.5 Dive time: set 5–995 minutes. Press SAVE.
PressLeft buttonPressMiddle buttonPressRight button
Manual p. 35Sound: 2 Dive settings » 2.10 All-silent mode. Leave it OFF (factory setting). ON turns off all audible alarms and needs code 313.
Manual p. 26
Reading the log after a dive
Only dives longer than 2 minutes are stored (p. 73).
On the time-of-day screen, press LOG (middle button).
PressMiddle button
Manual p. 12You first see dive statistics. Scroll with the ARROW buttons to a dive: number, date, time, max depth and dive time.
PressLeft buttonPressMiddle button
Manual p. 47Press ENTR to open a dive. Further pages show the profile graphic, more details and any warnings or alarms.
PressRight button
Manual p. 48Hold ENTR to go back, or hold left and right together to exit.
HoldRight buttonHold togetherLeft buttonHold togetherRight button
Manual p. 18
Battery
Rechargeable Li-ion battery; replacement only at an authorised SCUBAPRO service centre (p. 10).
The battery icon with the charge level is shown above the time of day.
Manual p. 9'Charge battery!' means the battery is critically low: the G2 will not start a dive. Charge it before diving.
Manual p. 9To charge, plug the USB cable into the G2 and a USB charger. Charge fully before first use.
Manual p. 8If deeply discharged, the screen stays blank at first: leave it charging at least 30 minutes without pressing buttons.
Manual p. 8Battery level is also shown in 8.1 Device information.
Manual p. 39
What the main screen shows
Screen layout can be changed to Light, Classic, Full or Graphical in 9.1 Screen configuration (p. 44).
Light layout (factory default): depth, dive time, tank pressure, no-stop time or remaining bottom time (RBT), O2 mix and a nitrogen bar graph.
Manual p. 74If deco is needed, the screen switches to Classic and shows the deepest stop, its time and total ascent time.
Manual p. 74Press MORE (middle) to show more data in one window, such as max depth, temperature, battery level, CNS%.
PressMiddle button
Manual p. 75Press BOOK (left) to set a bookmark.
PressLeft button
Manual p. 77Press LIGHT (right) to brighten the display. Hold the right button for the compass.
PressRight buttonHoldRight button
Manual p. 77After a dive deeper than 10 m / 30 ft, the safety stop timer starts at 5 m / 15 ft.
Manual p. 77
Pre-dive check
Tick each item before you get in the water.