Shearwater Peregrine setup guide
Also covers: Shearwater Peregrine
Two-button (MENU left, FUNC right) colour-screen computer with Air, Nitrox, 3 GasNx and Gauge modes. Rechargeable battery with wireless charging; vibration alerts, no beeper. Air mode is the factory default. The Peregrine TX is not covered by this manual.
Buttons
| Button | Where | What it does |
|---|---|---|
| MENU | left side of the housing | Open the menu; move through menus and options; while editing, change the value |
| FUNC | right side of the housing | Step through info screens; select a menu item or option; while editing, save the value |
Turn on / wake
Press MENU and FUNC at the same time to turn the computer on.
Press togetherMENUPress togetherFUNC
Manual p. 6A start-up screen shows for about 2 seconds, then the main screen appears.
Manual p. 6It also switches on by itself about 0.9 m / 3 ft underwater, but do not rely on this. Turn it on yourself before every dive.
Manual p. 6Press MENU on the main screen to open the menu. MENU moves through the items; FUNC selects one.
PressMENUPressFUNC
Manual p. 7To leave a menu, stop pressing buttons. After 10 seconds it returns to the main screen; saved values stay, half-finished edits are lost.
Manual p. 31To switch off on the surface, press MENU and, at Turn Off (first item), press FUNC. It is hidden during a dive and for 1 minute after it (default).
PressMENUPressFUNC
Manual p. 32
Date and time
System Setup cannot be opened during a dive (p. 38).
On the surface, press MENU repeatedly until System Setup appears, then press FUNC.
PressMENUPressFUNC
Manual p. 31Press MENU until the System Setup page (Date and Clock) appears, then press FUNC.
PressMENUPressFUNC
Manual p. 41On the Date line, press FUNC to edit. Press MENU to change the value and FUNC to save; repeat for each part.
PressFUNCPressMENU
Manual p. 41Move to Clock with MENU and set it the same way. You can choose AM/PM or 24-hour time.
PressMENUPressFUNC
Manual p. 41If the battery runs completely flat, set the date and clock again after charging.
Manual p. 48
Units (m/ft, °C/°F)
Press MENU until System Setup appears and press FUNC. Press MENU until Display Setup appears and press FUNC.
PressMENUPressFUNC
Manual p. 40On Depth Units, press FUNC, press MENU to choose Meters or Feet, then press FUNC to save.
PressFUNCPressMENU
Manual p. 40Press MENU to Temp Units, press FUNC, press MENU to choose °C or °F, then press FUNC to save.
PressMENUPressFUNC
Manual p. 40Depth and temperature units are set separately.
Manual p. 40
Water type (salt/fresh)
Press MENU until System Setup appears and press FUNC. Mode Setup is the first page; press FUNC to open it.
PressMENUPressFUNC
Manual p. 38Press MENU to the Salinity line, press FUNC, press MENU to choose Fresh, EN13319 or Salt, then press FUNC.
PressMENUPressFUNC
Manual p. 38EN13319 (between fresh and salt) is the default. This setting changes only the depth shown, not the decompression calculation.
Manual p. 38
Dive mode (Air / Nitrox / Gauge)
Mode can only be changed on the surface (System Setup is not available during a dive, p. 38).
Press MENU until System Setup appears and press FUNC. Mode Setup opens first; press FUNC.
PressMENUPressFUNC
Manual p. 38On the Mode line, press FUNC, press MENU to choose Air, Nitrox, 3 GasNx or Gauge, then press FUNC. Air is the default.
PressFUNCPressMENU
Manual p. 38Air is for one tank of air; Nitrox is for one tank of nitrox up to 40% O2. 3 GasNx is for several gases and planned deco.
Manual p. 9Gauge is a bottom timer: depth and time only, no decompression information.
Manual p. 9Changing to or from Gauge clears the tissue (nitrogen) data. Plan repeat dives with this in mind.
Manual p. 38There is no lock-out for missed stops; the computer warns you instead.
Manual p. 24
Nitrox O₂% and ppO₂ limit
The manual does not say that the O2 % resets to 21% by itself.
Set the Mode to Nitrox (see Dive mode).
Manual p. 38In Mode Setup, press MENU to Gas O2%, press FUNC, press MENU to change it to your analysed %, then press FUNC to save.
PressMENUPressFUNC
Manual p. 38Press MENU to MOD PPO2. The default is 1.40; only change it if your instructor tells you to. The MOD is shown below it.
PressMENU
Manual p. 38In Air mode the O2 is fixed at 21%.
Manual p. 38In Nitrox mode, Define Gas in the main menu also lets you edit the gas, even during a dive.
Manual p. 33
Conservatism / personal setting
Press MENU until System Setup appears and press FUNC. Press MENU until Deco Setup appears and press FUNC.
PressMENUPressFUNC
Manual p. 39On Conservatism, press FUNC, press MENU to choose Low (45/95), Med (40/85) or High (35/75), then press FUNC. Med is the default.
PressFUNCPressMENU
Manual p. 39The second number (GF High) controls your no-stop time: a lower number is more conservative and gives shorter no-stop times.
Manual p. 25A Custom GF option also exists. Do not use it unless you understand gradient factors.
Manual p. 39Deco Setup also sets the safety stop: Off, 3, 4 or 5 minutes, Adapt, or CntUp (count up).
Manual p. 39
Altitude
Not available on this computer
There is no altitude setting to change: it is fixed to Auto and the computer adjusts for altitude automatically (p. 40).
Audible alarms (depth / time)
The manual describes on-screen and vibration alerts only, no beeper.
Press MENU until System Setup appears and press FUNC. Press MENU until Alerts Setup appears and press FUNC.
PressMENUPressFUNC
Manual p. 40On Depth, press FUNC, press MENU to switch it on and change the depth, then press FUNC. Default: 40 m.
PressFUNCPressMENU
Manual p. 40 (default p. 21)Press MENU to Time and set it the same way. Default: 60 minutes, but switched off.
PressMENUPressFUNC
Manual p. 40 (default p. 21)Low NDL warns when no-stop time gets short (default 5 minutes). Vibration on/off is also on this page.
Manual p. 40 (default p. 21)Before diving, open Dive Setup and run Test Vibration to check you can feel it.
Manual p. 36When an alert appears, press either button to clear it.
Manual p. 19
Reading the log after a dive
Dive Log is only available on the surface (p. 36).
On the surface, press MENU until Dive Log appears, then press FUNC.
PressMENUPressFUNC
Manual p. 31At Display Log, press FUNC to see the list of dives.
PressFUNC
Manual p. 36Press MENU to move to a dive and FUNC to view it.
PressMENUPressFUNC
Manual p. 36The log shows max and average depth, dive number, date, start and end time, dive length, temperatures, mode, surface interval, GF and CNS.
Manual p. 36The depth profile is drawn in blue; deco stops are shown in red.
Manual p. 36
Battery
On the surface, check the battery icon on the main screen: blue is OK, yellow means charge soon, red means charge now.
Manual p. 11Press FUNC on the main screen to step through the info screens; one shows the battery voltage.
PressFUNC
Manual p. 18If LOW BATTERY appears, recharge before diving.
Manual p. 22Charge it flat on the wireless charging dock (USB powered). A full charge takes about 2 hours.
Manual p. 47If the battery goes completely flat, settings are kept but the clock must be reset and tissue (nitrogen) data is lost.
Manual p. 48For storage, charge to 100% and top up every 3 months.
Manual p. 47
What the main screen shows
Top left: current depth. Next to it: dive time in minutes and seconds. On the surface this shows the surface interval and battery icon.
Manual p. 10Ascent rate arrows: white under 9 m (30 ft) per minute, yellow up to 18 m (60 ft) per minute, flashing red above that.
Manual p. 11NDL is the no-stop time left in minutes. It turns yellow when it gets low.
Manual p. 12Below 11 m (35 ft) a safety stop counter appears. It counts down from 6 m (20 ft) while you stay between 2.4 and 8.3 m (7–27 ft).
Manual p. 23If NDL reaches 0, the stop depth and time replace the safety stop. Go to that depth and wait.
Manual p. 12Bottom row: current gas, max depth, time of day and temperature. Press FUNC for more data, MENU to return.
PressFUNCPressMENU
Manual p. 10
Pre-dive check
Tick each item before you get in the water.