Suunto Zoop Novo setup guide
Also covers: Suunto Zoop Novo
Wrist dive computer with four buttons (SELECT, MODE, UP, DOWN) using Suunto RGBM. Air, Nitrox (one gas, up to 50%), Gauge and Free modes; manual altitude setting; battery changed by a Suunto service centre.
Buttons
| Button | Where | What it does |
|---|---|---|
| SELECT | front, upper left (per the Quick Guide diagram) | Enter / confirm a setting; in a dive: add a bookmark |
| MODE | front, upper right (per the Quick Guide diagram) | Change main mode (TIME, DIVE, PLAN, MEM); exit settings; in a dive: backlight |
| DOWN | front, lower left (per the Quick Guide diagram) | Scroll / change value; hold to open settings |
| UP | front, lower right (per the Quick Guide diagram) | Scroll / change value |
Turn on / wake
Press and hold any button until the display turns on.
Manual p. 7Press MODE to move between the four main modes: TIME, DIVE, PLAN and MEM.
PressMODE
Manual p. 7Press MODE to go to DIVE before every dive. It runs a self-test, then shows altitude and personal settings, gas, MOD, PO2 and battery.
PressMODE
Manual p. 9It switches to DIVE by itself below 1.2 m / 4 ft, unless dive mode has been set to Off.
Manual p. 7To leave any settings menu, press MODE.
PressMODE
Manual p. 7The display switches off after 30 minutes without use. Press any button to wake it.
Manual p. 26
Date and time
In TIME mode, press and hold DOWN to open the general settings.
HoldDOWN
Manual p. 14Press UP to scroll to Time, then press SELECT.
PressUPPressSELECT
Manual p. 14Set the hours with UP or DOWN and press SELECT. Do the same for minutes and seconds.
PressUPPressDOWNPressSELECT
Manual p. 14Choose 12 h or 24 h format with UP or DOWN, press SELECT, then press MODE to exit.
PressUPPressSELECTPressMODE
Manual p. 14For the date: hold DOWN in TIME mode, press UP to Date, then press SELECT.
HoldDOWNPressUPPressSELECT
Manual p. 14Set the year with UP or DOWN and press SELECT. Repeat for month and day, then press MODE to exit.
PressUPPressSELECTPressMODE
Manual p. 14
Units (m/ft, °C/°F)
In TIME mode, press and hold DOWN to open the general settings.
HoldDOWN
Manual p. 15Press UP to scroll to Units, then press SELECT.
PressUPPressSELECT
Manual p. 15Press DOWN to switch between Metric and Imperial, then press SELECT to confirm.
PressDOWNPressSELECT
Manual p. 15Press MODE to exit. The manual offers one unit-system choice, not separate depth and temperature settings.
PressMODE
Manual p. 15
Water type (salt/fresh)
Not available on this computer
The manual describes no salt/fresh water setting: the dive-mode settings lists (Air, Nitrox, Gauge, Free, p. 21–22) and the general settings do not include one.
Dive mode (Air / Nitrox / Gauge)
Some settings cannot be changed until 5 minutes after a dive (p. 21).
In TIME mode, press and hold DOWN to open the general settings.
HoldDOWN
Manual p. 20Press SELECT to open Dive Mode.
PressSELECT
Manual p. 20Choose Air, Nitrox, Gauge, Free or Off with UP or DOWN, then press SELECT. Air is the default.
PressUPPressDOWNPressSELECT
Manual p. 20Press MODE to exit.
PressMODE
Manual p. 20Gauge is a bottom timer only: no decompression or no-deco information at all.
Manual p. 22After a dive in Gauge mode, the no-fly time is 48 hours.
Manual p. 29Off turns dive mode off completely: it will not start a dive by itself under water, and PLAN is hidden. Never dive with it set to Off.
Manual p. 20If you skip a decompression stop for more than 3 minutes, the algorithm locks for 48 hours and shows Er instead of deco information.
Manual p. 24
Nitrox O₂% and ppO₂ limit
Only one gas mix. The defaults are 21% O2 and PO2 1.4 bar (p. 21).
Select Nitrox as the dive mode (see Dive mode), then press MODE until you are in DIVE.
PressMODE
Manual p. 20In DIVE (Nitrox), press and hold DOWN to open the dive settings.
HoldDOWN
Manual p. 21Press SELECT to open the Nitrox setting.
PressSELECT
Manual p. 21Set the O2 % to match your analysed tank with UP or DOWN, then press SELECT. The range is 21–50%.
PressUPPressDOWNPressSELECT
Manual p. 21Set the PO2 limit with UP or DOWN and press SELECT. The default is 1.4 bar.
PressUPPressDOWNPressSELECT
Manual p. 22Press MODE to exit, then check the gas and MOD shown on the pre-dive screen.
PressMODE
Manual p. 22An O2 setting of 22% or more stays until you change it. It does NOT go back to 21% by itself.
Manual p. 22
Conservatism / personal setting
Press MODE to go to DIVE (Air or Nitrox), then press and hold DOWN.
PressMODEHoldDOWN
Manual p. 25Press SELECT to open the Personal Altitude settings.
PressSELECT
Manual p. 25Press UP to change the Personal setting (0, 1 or 2), then press SELECT.
PressUPPressSELECT
Manual p. 250 is for ideal conditions (default). 1 is conservative and 2 more conservative, for risk factors like cold water, tiredness or poor fitness.
Manual p. 25Next the Altitude setting appears: press SELECT to keep it, then MODE to exit.
PressSELECTPressMODE
Manual p. 25Deepstops are on by default in Air and Nitrox. Turn them on or off under Deepstop in the same dive settings.
Manual p. 27
Altitude
Altitude is a manual setting; it is not detected automatically.
In DIVE mode, press and hold DOWN, then press SELECT to open Personal Altitude.
HoldDOWNPressSELECT
Manual p. 25Press SELECT to keep the Personal setting and move to Altitude.
PressSELECT
Manual p. 25Press UP to choose 0 (0–300 m / 0–980 ft, default), 1 (300–1500 m / 980–4900 ft) or 2 (1500–3000 m / 4900–9800 ft). Press SELECT.
PressUPPressSELECT
Manual p. 25Press MODE to exit.
PressMODE
Manual p. 25Wait at least 3 hours after arriving at altitude before diving. Do not use it above 3000 m / 10000 ft.
Manual p. 30
Audible alarms (depth / time)
Leave Tones on. With a low-battery warning the buzzer cannot sound (p. 10).
Depth alarm: in DIVE mode, press and hold DOWN, press UP to Depth Alarm, then press SELECT.
HoldDOWNPressUPPressSELECT
Manual p. 18Press UP to turn it on or off and press SELECT. Set the depth with UP or DOWN, press SELECT, then MODE. Default: 30 m / 100 ft.
PressUPPressSELECTPressMODE
Manual p. 18Dive time alarm: in DIVE mode, hold DOWN and scroll to ALARM TIME. Press UP to turn it on, then SELECT.
HoldDOWNPressUPPressSELECT
Manual p. 24Set the minutes with UP or DOWN, press SELECT, then press MODE to exit.
PressUPPressSELECTPressMODE
Manual p. 24Sound: in TIME mode, hold DOWN, scroll to Tones and press SELECT. Choose on or off and press SELECT. With tones off there are no audible alarms.
HoldDOWNPressUPPressSELECT
Manual p. 31When an alarm goes off, press any button to acknowledge it.
Manual p. 18
Reading the log after a dive
Press MODE until you see MEM.
PressMODE
Manual p. 18Choose History or Logbook with UP or DOWN.
PressUPPressDOWN
Manual p. 19History shows total dive hours, number of dives and maximum depth (scuba and free dive history are separate).
Manual p. 19Each log has a main page: max depth, date, dive mode letter, start time, dive number, gas % and dive time.
Manual p. 19Further pages show surface time, average depth, warnings, OLF% and the depth profile with water temperature. Press UP to scroll the profile.
PressUP
Manual p. 20Press MODE to go back, and MODE again to exit.
PressMODE
Manual p. 19
Battery
Enter DIVE mode: the self-test checks the battery and shows Battery OK or a low battery warning.
PressMODE
Manual p. 9If the low battery icon appears on the surface, or the display looks faded, the battery should be replaced. Do not dive until it is.
Manual p. 32Cold or long storage can cause a false low warning. Re-enter DIVE mode to check again.
PressMODE
Manual p. 10With the low battery warning, the backlight and sound do not work.
Manual p. 10The battery voltage is also shown under Version in the general settings (TIME mode, hold DOWN).
HoldDOWNPressUPPressSELECT
Manual p. 28Battery replacement must be done by an authorised Suunto service centre.
Manual p. 32
What the main screen shows
The pre-dive self-test shows altitude and personal settings, MOD, gas (O2 %) and PO2.
Manual p. 9NO DEC TIME is the minutes left without a deco stop. If it reaches zero it changes to ASC TIME with a CEILING depth and an up arrow.
Manual p. 15The ascent rate is the bar on the right side. If the lower segment blinks you are too fast; SLOW blinks above 10 m/min (33 ft/min).
Manual p. 13STOP with a 3-minute countdown is the safety stop between 3 and 6 m (10–20 ft) after dives deeper than 10 m (30 ft).
Manual p. 26In Nitrox, OLF% shows the oxygen exposure.
Manual p. 31Press MODE during the dive for the backlight. Press SELECT to add a bookmark.
PressMODEPressSELECT
Manual p. 14After the dive, the airplane symbol means do not fly; the No Fly field shows the countdown in DIVE mode.
Manual p. 28
Pre-dive check
Tick each item before you get in the water.